Function 18:
General reset of keypad
Shifting settings to the initial manufacturer's state
For example, C P 18 P 1234567 P 1234567 P |
Function 19:
To turn off the mode of keypad operation as a switcher
Tis function turn the function 20 off.
For example, C P 19 P 1234567 P |
Function 20:
To turn on the mode of keypad operation as a switcher
The mode is used when it is necessary to turn any device on and keep it at this condition for unlimited time. At this mode the keypad operates as a switcher, i.e. when a code is dialled, the executive relay will turn on and keep in such position unless a code is entered again or AK-04 power supply is turned on temporary, in that case all settings and codes will save. While the executive relay is turned the right green light-emitting diode will lighten on the keypad for all this time.
For example, C P 20 P 1234567 P |
Function 23:
To set time pause till the executive relay will operate
For code-matching protection there is the additional temporal pause after the code is dialled and before the executive relay operates. The pause is setted up from 0.5 to 9 seconds. To set up 0.5-period of time is to enter 0. (Increment - 1 second). This function turns on this mode.
For example, C P 23 P 3 P 1234567 P |
Function 24:
Time of keeping the executive relay in turning-on position
This function set up a temporal period of keeping the executive relay in turning-on position from 0.5 to 9 second. To set up 0.5-period of time is to enter 0.
For example, C P 24 P 4 P 1234567 P |
When 10 seconds comes to the end after pressing any buttons the keypad will shift into C (escape) condition!
|