Function 9:
To switch the confirmation of pressing the buttons by blinking the light-emitting diode on
The function switches confirmation of pressing the keypad's buttons by blinking the light-emitting diode on. The mode has setted by default.
For example, C P 9 P 1234567 P |
Function 10:
To switch the confirmation of pressing the buttons by blinking the light-emitting diode off
The function switches confirmation of pressing the keypad's buttons by blinking the light-emitting diode on. The mode has setted by default.
For example, C P 10 P 1234567 P |
Function 11:
To switch the confirmation of pressing the buttons by the buzzer sound on
The function switches sound confirmation of pressing the keypad's buttons on.
For example, C P 11 P 1234567 P |
Function 12:
To switch the confirmation of pressing the buttons by the buzzer sound off
The function switches the sound confirmation of pressing the keypad's buttons off. The mode has setted by default.
For example, C P 12 P 1234567 P |
CAUTION: After changing codes it necessary to make sure that code have been set up correctly. If the executive relay doesnt operate with a new code then it needs:
Open the keypad's cover.
Press and keep pressing for 6 seconds RESET BUTTON placed on the control plate, in that case the keypad returns above-set-up codes and modes to factory designation. This operation should be done when power supply is not turned off.
After this close the cover and enter new codes.
Test code operations.
We recommend insistently to change the master code after pressing the button RESET, and also after mounting the KEYPAD.
|