Electronic door locks with the invisible code setting DORI, the lock without keys, is the safe protection of your private life and your secrets
DORI door locks . Price list DORI - the electronic code lock RIFF - the electronic motor lock RIFF-12v - the electronic motor mortise door lock The hidden code dialling keypad AK-04 DORI door locks . Contacts

ak-04|changing functions|  Changing access codes



AK-04 - the access keypad
Technical characteristics
Exploitation
Installation
Programming
Changing codes
Controlling indication
Controlling alarm signal
Service functions
Manufacturer's warranty
KNOW-HOW
Hidden code setting
Modes of operation
Securing against code matching and opening under duress
Codes of access
Cross-bar system
DOWNLOAD
The user manual of the code dialling keypad AK-04
Programming notes

All Documentations...
PHOTOGALLERY
 
FRIENDS

Into the keypad AK-04, to combine with the “DORI-3” lock when a master code is set up, the command of short master code setting without additional confirmation of a new master code is entered. The number and format of function coincide with analogous function in the “DORI-3”. But such entering the master code is not safety because a mistake at entering the master code will bring to need to reinstal the keypad for pressing the RESET button. So it is recommended insistently to use function 0 to set up or change master code.

Functions 1 and 0 are analogous by them actions and interchangeable.

At the wrong command entering the left light-emitting diode indicator will lighten long for a second.

Function 0:
To change the master code
The master code (Administrator's code) allows opening the executive relay, setting up a user's code and keypad's function. The master code couldnot be cancelled and blocked.
C P 0 P [MC] P [nMC] P [nMC] P
For example, C P 0 P 1234567 P 7654321 P 7654321 P
Function 1:
To set up a new main code
Successful completing of code changing will be confirmed by the triple blinking of the left red indicator.
C P 1 P [mainC] P [NmainC] P
For example, C P 1 P 1357 P 7531 P
Function 2:
To set and change a user's code
User's code can be set and changed by the administrator by means of the master code.
It can be changed by user if he has such permission. In this case in the algorithm [MC] is changed into [UC].
C P 2 P [UN (1-24)] P [MC] P [nUC] P [nUC] P
For example, C P 2 P 10 P 1234567 P 1976 P 1976 P
Function 3:
The single-use code
At setting this mode the code couldnt be used repeatedly after a single usage. The used code has not be lost and it can be activized again by means of functions 3, 4, 5 or 7. At setting the code as a code for a single use the function 3 enables using the code if this mode is cancelled by the function 6 or when the single usage has been already performed.
C P 3 P [UN (1-24)] P [MC] P
For example, C P 3 P 7 P 1234567 P
Function 4:
The multiple-use code
In order to make the code multiple it is necessary to set the function 4. Application of this function enables using the code if this mode is cancelled by the function 6 or when the single usage has been already performed.
C P 4 P [UN (1-24)] P [MC] P
For example, C P 4 P 5 P 1234567 P
Function 5:
To permit a user's code to be used
It is used to controll the quantity of users and limit it. At setting the mode the user's code has become permitted automatically.
C P 5 P [UN (1-24)] P [MC] P
For example, C P 5 P 8 P 1234567 P
Function 6:
To cancel a user's code
If it is necessary a user's code can be cancelled temporarily or constantly. In this case this code has not been lost and it can be activized again by means of functions 3, 4, 5 or 7. By the function 6 the user's code can be disabled temporarily, for instance, on the holiday's time.
C P 6 P [UN (1-24)] P [MC] P
For example, C P 6 P 15 P 1234567 P
Function 7:
To permit for a user to change his code
A user can or cannot have an oppoertunity to change his own code by the functions 7 and 8. By default the user cannot be done it. Application of functions 7 enables using code if this mode is cancelled by the function 6 or when the single usage has been already performed. At setting this mode the user's code has become multiple automatically.
C P 7 P [UN (1-24)] P [MC] P
For example, C P 7 P 3 P 1234567 P
Function 8:
To prohibit for a user to change his code
Application of this function prohibits user to change his code himself. The mode is set up be default.
C P 8 P [UN (1-24)] P [MC] P
For example, C P 8 P 13 P 1234567 P

CAUTION: After changing codes it necessary to make sure that code have been set up correctly. If the executive relay doesnt operate with a new code then it needs:

      Open the keypad's cover.
      Press and keep pressing for 6 seconds “RESET BUTTON” placed on the control plate, in that case the keypad returns above-set-up codes and modes to factory designation. This operation should be done when power supply is not turned off.
      After this close the cover and enter new codes.
      Test code operations.

      We recommend insistently to change the master code after pressing the button “RESET”, and also after mounting the KEYPAD.

      Set up a master code as long as it is possible!

 
Sevastopol 1994 - 2008