ATTENTION! Setting and changing codes must be done by opened the door or set the switcher of the modes of operation in the "OPEN" position.
Function 18:
General reset of lock
Shifting settings to the initial manufacturer's state
For example, C P 18 P 1234567 P 1234567 P |
Function 19:
Permission of opening by EXIT button
To enble free exiting on pressing EXIT button.
For example, C P 19 P 1234567 P |
Function 20:
Prohibition of opening by the EXIT button
To prohibit opening door by means of the EXIT button. In this case only by means of the line of the external controlling system opening can be or on opening by means of code.
For
example, C P 20 P 1234567 P
|
Function 23:
To set time pause till the lock will be opened
The additional code-matching protection is
pause after the code is dialled and before lock will
be unfastened. The pause is setted up from 0.5 to 9
seconds. To set up 0.5-period of time is to enter 0.
(Increment - 1 second)
For example, C P 23 P 3 P 1234567 P |
Function 24:
Time of keeping lock in OPEN position
Time period of keeping the lock in OPEN position
from 0.5 to 9 second. To set up 0.5-period of time is
to enter 0.
2 seconds are setted by default.
For example, C P 24 P 4 P 1234567 P |
NB! After changing of all codes you should make sure codes to be setted correctly. If the lock has not unfastened by means of the new code it is necessary to remove lock's cover and hold the "RESET" button pressed for 6 seconds which is situated on the control card under the batteries holder. In this case all previous codes and settings will shift to the initial manufacturer's state.
|